TrinityTrinity
Transparency

Third-party lab results

Every Trinity compound is independently tested by ISO 17025-accredited laboratories. Results include HPLC purity analysis, mass spectrometry verification, endotoxin testing, and ICP-MS heavy metals screening. No in-house shortcuts — ever.

ISO 17025 Accredited Lab

Independent third-party testing only

≥98% Purity Guaranteed

HPLC-verified on every batch

Endotoxin & Heavy Metals

LAL plus ICP-MS heavy metals screening

COA On Every Order

Physical and digital COA ships with every order

BPC-157

Recovery
≥99% Pure

Test Results Summary

HPLC Purity99.2%
Molecular Weight Verified✓ Yes
Endotoxin (LAL)<1.0 EU/mg
Heavy Metals (ICP-MS)Pass — <10 ppm (ICP-MS)
HPLCMass SpecLAL EndotoxinHeavy Metals
Batch: TR-BPC157-2026-001 · Tested: Q1 2026 · Lab: ISO 17025

Retatrutide

Metabolic
≥98% Pure

Test Results Summary

HPLC Purity98.6%
Molecular Weight Verified✓ Yes
Endotoxin (LAL)<1.0 EU/mg
Heavy Metals (ICP-MS)Pass — <10 ppm (ICP-MS)
HPLCMass SpecLAL EndotoxinHeavy Metals
Batch: TR-RETA-2026-001 · Tested: Q1 2026 · Lab: ISO 17025

TB-500

Recovery
≥98.5% Pure

Test Results Summary

HPLC Purity98.7%
Molecular Weight Verified✓ Yes
Endotoxin (LAL)<1.0 EU/mg
Heavy Metals (ICP-MS)Pass — <10 ppm (ICP-MS)
HPLCMass SpecLAL EndotoxinHeavy Metals
Batch: TR-TB500-2026-001 · Tested: Q1 2026 · Lab: ISO 17025

Semaglutide

Metabolic
≥98.5% Pure

Test Results Summary

HPLC Purity98.9%
Molecular Weight Verified✓ Yes
Endotoxin (LAL)<1.0 EU/mg
Heavy Metals (ICP-MS)Pass — <10 ppm (ICP-MS)
HPLCMass SpecLAL EndotoxinHeavy Metals
Batch: TR-SEMA-2026-001 · Tested: Q1 2026 · Lab: ISO 17025

CJC-1295 / Ipamorelin Stack

Anti-Aging
≥98% Pure

Test Results Summary

HPLC Purity98.4%
Molecular Weight Verified✓ Yes
Endotoxin (LAL)<1.0 EU/mg
Heavy Metals (ICP-MS)Pass — <10 ppm (ICP-MS)
HPLCMass SpecLAL EndotoxinHeavy Metals
Batch: TR-CJCIPM-2026-001 · Tested: Q1 2026 · Lab: ISO 17025

Tirzepatide

Metabolic
≥98% Pure

Test Results Summary

HPLC Purity98.3%
Molecular Weight Verified✓ Yes
Endotoxin (LAL)<1.0 EU/mg
Heavy Metals (ICP-MS)Pass — <10 ppm (ICP-MS)
HPLCMass SpecLAL EndotoxinHeavy Metals
Batch: TR-TIRZ-2026-001 · Tested: Q1 2026 · Lab: ISO 17025

GHK-Cu

Anti-Aging
≥99% Pure

Test Results Summary

HPLC Purity99.5%
Molecular Weight Verified✓ Yes
Endotoxin (LAL)<0.5 EU/mg
Heavy Metals (ICP-MS)Pass — <10 ppm (ICP-MS)
HPLCMass SpecLAL EndotoxinHeavy Metals
Batch: TR-GHKCU-2026-001 · Tested: Q1 2026 · Lab: ISO 17025

NAD+

Anti-Aging
≥99% Pure

Test Results Summary

HPLC Purity99.3%
Molecular Weight Verified✓ Yes
Endotoxin (LAL)<1.0 EU/mg
Heavy Metals (ICP-MS)Pass — <10 ppm (ICP-MS)
HPLCMass SpecLAL EndotoxinHeavy Metals
Batch: TR-NAD-2026-001 · Tested: Q1 2026 · Lab: ISO 17025

Bacteriostatic Water 10ml

Supplies
USP Grade

Test Results Summary

HPLC Purity0.9% benzyl alcohol (assay 98.6–101.2%)
Molecular Weight Verified✓ Yes
Endotoxin (LAL)<0.25 EU/mL
Heavy Metals (ICP-MS)Pass — <1 ppm (ICP-MS)
HPLCMass SpecLAL EndotoxinHeavy Metals
Batch: TR-BAC-2026-001 · Tested: Q1 2026 · Lab: ISO 17025

Glutathione

Wellness
≥99% Pure

Test Results Summary

HPLC Purity99.1%
Molecular Weight Verified✓ Yes
Endotoxin (LAL)<1.0 EU/mg
Heavy Metals (ICP-MS)Pass — <10 ppm (ICP-MS)
HPLCMass SpecLAL EndotoxinHeavy Metals
Batch: TR-GLUT-2026-001 · Tested: Q1 2026 · Lab: ISO 17025

PT-141

Sexual Health
≥99% Pure

Test Results Summary

HPLC Purity99.0%
Molecular Weight Verified✓ Yes
Endotoxin (LAL)<1.0 EU/mg
Heavy Metals (ICP-MS)Pass — <10 ppm (ICP-MS)
HPLCMass SpecLAL EndotoxinHeavy Metals
Batch: TR-PT141-2026-001 · Tested: Q1 2026 · Lab: ISO 17025

MOTS-c

Metabolic
≥98.5% Pure

Test Results Summary

HPLC Purity98.8%
Molecular Weight Verified✓ Yes
Endotoxin (LAL)<1.0 EU/mg
Heavy Metals (ICP-MS)Pass — <10 ppm (ICP-MS)
HPLCMass SpecLAL EndotoxinHeavy Metals
Batch: TR-MOTSC-2026-001 · Tested: Q1 2026 · Lab: ISO 17025

Glow Stack

Anti-Aging
≥98% Pure

Test Results Summary

HPLC Purity98.2% (blend avg)
Molecular Weight Verified✓ Yes
Endotoxin (LAL)<1.0 EU/mg
Heavy Metals (ICP-MS)Pass — <10 ppm (ICP-MS)
HPLCMass SpecLAL EndotoxinHeavy Metals
Batch: TR-GLOW-2026-001 · Tested: Q1 2026 · Lab: ISO 17025

KPV

Recovery
≥99% Pure

Test Results Summary

HPLC Purity99.4%
Molecular Weight Verified✓ Yes
Endotoxin (LAL)<0.5 EU/mg
Heavy Metals (ICP-MS)Pass — <10 ppm (ICP-MS)
HPLCMass SpecLAL EndotoxinHeavy Metals
Batch: TR-KPV-2026-001 · Tested: Q1 2026 · Lab: ISO 17025

DSIP

Wellness
≥99% Pure

Test Results Summary

HPLC Purity99.1%
Molecular Weight Verified✓ Yes
Endotoxin (LAL)<1.0 EU/mg
Heavy Metals (ICP-MS)Pass — <10 ppm (ICP-MS)
HPLCMass SpecLAL EndotoxinHeavy Metals
Batch: TR-DSIP-2026-001 · Tested: Q1 2026 · Lab: ISO 17025
Methodology

About our testing process

HPLC Analysis

High-Performance Liquid Chromatography confirms peptide identity and purity percentage by separating and measuring compound concentration against reference standards.

Mass Spectrometry

Molecular weight verification confirms the exact compound is present with no substitutions or adulterants. Every batch is matched against the target molecular mass.

ICP-MS Heavy Metals Screening

Inductively Coupled Plasma Mass Spectrometry screens every batch for lead, arsenic, cadmium and mercury, confirming residues fall well below USP <232> elemental impurity limits.

LAL Endotoxin Testing

Limulus Amebocyte Lysate (LAL) testing detects bacterial endotoxins to ensure compounds meet injectable-grade safety thresholds for research environments.

COA Notice

Certificates of Analysis are provided for transparency and research verification purposes only. Test results reflect the specific batch indicated. Trinity products are sold strictly for in-vitro research and laboratory use only. COA documentation does not imply suitability for human or animal use.